N.P.S of 750-800 microns were put on the
plate in the lab-scale Drug layering 380 machine. Drug layering
machine was adjusted to suitable RPM and the Binder solution
was sprayed. The baffle was used to increase the tumbling
effect. After a few seconds iron powder was sprayed with the
help of pneumatic nozzles and powder feeder. The baffle was
again used to improve the layering. The process was continued
till the complete powder was over and the material was discharged
for drying.
Result
The powder was layered uniformly sieve analysis showed only
1.2% of the pellets were above 900 microns and rest were uniform.
|